4 Parameter List
4 - 14
High-function General-purpose Inverter 3G3RX-V1 User’s Manual (I578-E1)
A061 1st Frequency
Upper Limit
0.00: Disabled (Function not
active)
1st Frequency Lower Limit (A062)
to 1st Maximum Frequency (A004)
0.00 Disabled Enabled Hz 7-42
A261 2nd Frequency
Upper Limit
0.00: Disabled (Function not
active)
2nd Frequency Lower Limit (A262)
to 2nd Maximum Frequency
(A204)
0.00
A062 1st Frequency
Lower Limit
0.00: Disabled (Function not
active)
Starting Frequency (b082) to 1st
Frequency Upper Limit (A061)
0.00 Disabled Enabled Hz
A262 2nd Frequency
Lower Limit
0.00: Disabled (Function not
active)
Starting Frequency (b082) to 2nd
Frequency Upper Limit (A261)
0.00
A063 Jump Frequency 1 0.00: Disabled (Function not
active)
0.01 to 99.99
100.0 to 400.0
0.00 Disabled Enabled Hz 7-44
A064 Jump Frequency
Width 1
0.0 to 10.0 0.50
A065 Jump Frequency 2 0.00: Disabled (Function not
active)
0.01 to 99.99
100.0 to 400.0
0.00
A066 Jump Frequency
Width 2
0.0 to 10.0 0.50
A067 Jump Frequency 3 0.00: Disabled (Function not
active)
0.01 to 99.99
100.0 to 400.0
0.00
A068 Jump Frequency
Width 3
0.0 to 10.0 0.50
A069 Acceleration Stop
Frequency
0.00 to 99.99
100.0 to 400.0
0.00 Disabled Enabled Hz 7-45
A070 Acceleration Stop
Time
0.0 to 60.0 0.0 Disabled Enabled s
Parameter
No.
Function name Monitor or data range
Default
data
Changes during
operation
Unit Page
Normal
b031 = 10