4 Parameter List
4 - 16
High-function General-purpose Inverter 3G3RX-V1 User’s Manual (I578-E1)
Parameter
No.
Function name Monitor or data range
Default
data
Changes during
operation
Unit Page
Normal
b031 = 10
A085 Operation Mode
Selection
Heavy
load
(CT)
00: Normal operation
01: Energy-saving
operation
02: Automatic operation
00 Disabled Disabled – 7-53
Light
load
(VT)
00: Normal operation
01: Energy-saving
operation
00 Disabled Disabled –
A086 Energy-saving
Response/
Accuracy
Adjustment
0.0 to 100.0 50.0 Enabled Enabled –
A092 1st Acceleration
Time 2
0.01 to 99.99
100.0 to 999.9
1000. to 3600.
10.0
*1
Enabled Enabled s 7-55
A292 2nd Acceleration
Time 2
10.0
*1
A392 3rd Acceleration
Time 2
10.0
*1
A093 1st Deceleration
Time 2
10.0
*1
A293 2nd Deceleration
Time 2
10.0
*1
A393 3rd Deceleration
Time 2
10.0
*1
A094 1st 2-step
Acceleration/
Deceleration
Selection
00: 2CH terminal (Switched by
multi-function Input: “09”)
01: Switched by setting
(A095/A295/A096/A296)
02: Switched only during
forward/reverse switching
00 Disabled Disabled –
A294 2nd 2-step
Acceleration/
Deceleration
Selection
00
A095 1st 2-step
Acceleration
Frequency
0.00 to 99.9
100.0 to 400.0
0.00 Disabled Disabled Hz
A295 2nd 2-step
Acceleration
Frequency
0.00
A096 1st 2-step
Deceleration
Frequency
0.00 Disabled Disabled Hz
A296 2nd 2-step
Deceleration
Frequency
0.00
A097 Acceleration
Pattern Selection
00: Line
01: S-shape curve
02: U-shape curve
03: Inverted U-shape curve
04: EL-S-shape curve
01
*1
Disabled Disabled – 7-57
A098 Deceleration
Pattern Selection
01
*1
Disabled Disabled –