Loading...
4 Parameter List
4 - 30
High-function General-purpose Inverter 3G3RX-V1 User’s Manual (I578-E1)
Parameter
No.
Function name Monitor or data range
Default
data
Changes during
operation
Unit Page
Normal
b031 = 10
C021 Multi-function
Output P1
Selection
00: RUN (Signal during RUN)
01: FA1 (Constant speed arrival signal)
02: FA2 (Set frequency exceeded signal)
03: OL (Overload warning)
04: OD (Excessive PID deviation)
05: AL (Alarm signal)
06: FA3 (Set-frequency only signal)
07:
OTQ (Overtorque/Undertorque signal)
08:
IP (Signal during momentary power interruption)
09: UV (Signal during undervoltage)
10: TRQ (Torque limit)
11: RNT (RUN time over)
12: ONT (Power ON time over)
13: THM (Electronic thermal warning)
19: BRK (Brake release)
20: BER (Brake error)
21: ZS (0 Hz detection signal)
22: DSE (Excessive speed deviation)
23: POK (Position ready)
24: FA4 (Set frequency exceeded signal 2)
25: FA5 (Set-frequency only signal 2)
26: OL2 (Overload warning 2)
27:
FVDc (Analog FV disconnection detection)
28:
FIDc (Analog FI disconnection detection)
29:
FEDc (Analog FE disconnection detection)
31: FBV (PID feedback comparison signal)
32:
NDc (Communications disconnection detection)
33: LOG1 (Logic operation output 1)
34: LOG2 (Logic operation output 2)
35: LOG3 (Logic operation output 3)
36: LOG4 (Logic operation output 4)
37: LOG5 (Logic operation output 5)
38: LOG6 (Logic operation output 6)
39: WAC (Capacitor life warning signal)
40: WAF (Cooling fan life warning signal)
41: FR (Starting contact signal)
42: OHF (Cooling fin overheat warning)
43: LOC (Low current signal)
44: MO1 (General-purpose output 1)
45: MO2 (General-purpose output 2)
46: MO3 (General-purpose output 3)
47: MO4 (General-purpose output 4)
48: MO5 (General-purpose output 5)
49: MO6 (General-purpose output 6)
50: IRDY (Operation ready)
51: FWR (Forward run signal)
52: RVR (Reverse run signal)
53: MJA (Fatal fault signal)
54:
WCFV (Window comparator FV)
55: WCFI (Window comparator FI)
56:
WCFE (Window comparator FE)
63: OPO (Option)
no: NO (No allocation)
00 Disabled Enabled 5-59
C022 Multi-function
Output P2
Selection
01
C023 Multi-function
Output P3
Selection
03
C024 Multi-function
Output P4
Selection
07
C025 Multi-function
Output P5
Selection
40
C026 Multi-function
Relay Output (MA,
MB) Function
Selection
05
Multi-function output terminals

Table of Contents

Related product manuals