7 Detailed Functions
7 - 6
High-function General-purpose Inverter 3G3RX-V1 User’s Manual (I578-E1)
Use this function to display the estimated output torque value of the inverter.
The data display LED “%” is lit while the value of d012 is displayed.
This parameter value can be displayed only when the sensorless vector control, 0-Hz sensorless
vector control, or sensor vector control mode is selected.
Use this function to display the output voltage of the inverter.
The data display LED “V” is lit while the value of d013 is displayed.
Set the Motor Rated Voltage Selection (A082) correctly to obtain a correct parameter value.
Use this function to display the input power (instantaneous value) of the inverter.
The data display LED “kW” (“V” and “A”) is lit while the value of d014 is displayed.
Output Torque Monitor [d012]
Parameter No. Function name Data Default data Unit
d012 Output Torque Monitor
–200. to 200. (Displayed in increments of
1%)
–%
Output Voltage Monitor [d013]
Parameter No. Function name Data Default data Unit
d013 Output Voltage Monitor
0.0 to 600.0 (Displayed in increments of
0.1 V)
–V
Input Power Monitor [d014]
Parameter No. Function name Data Default data Unit
d014 Input Power Monitor
0.0 to 999.9 (Displayed in increments of
0.1 kW)
–kW