7 - 9
7 Detailed Functions
High-function General-purpose Inverter 3G3RX-V1 User’s Manual (I578-E1)
7-1 Monitor Mode (Group d)
7
Precautions for Correct UsePrecautions for Correct Use
The inverter calculates the capacitor life once every 10 minutes. If the power supply is turned
on/off more frequently than this cycle, the inverter cannot evaluate the capacitor life
successfully.
If the Cooling Fan Operation (b092) is set to 01, the rotation speed of the cooling fan will be
evaluated as normal while the cooling fan is stopped.
Use this function to display the line number of the program that is executed while a DriveProgramming
function is active.
For details, refer to “DriveProgramming User’s Manual (I580)”.
Use this function to display the program number of the downloaded DriveProgramming program.
However, you need to set a program number during programming.
For details, refer to “DriveProgramming User’s Manual (I580)”.
Use these functions to monitor the result of the calculation performed in the DriveProgramming
program.
For details, refer to “DriveProgramming User’s Manual (I580)”.
Program Counter (DriveProgramming) [d023]
Parameter No. Function name Data Default data Unit
d023 Program Counter 0 to 1024 (Displayed in increments of 1)
Program Number Monitor (DriveProgramming) [d024]
Parameter No. Function name Data Default data Unit
d024 Program Number Monitor
0000 to 9999 (Displayed in increments
of 1)
––
User Monitor 0 to 2 (DriveProgramming) [d025 to d027]
Parameter No. Function name Data Default data Unit
d025 User Monitor 0
–2147483647 to 2147483647
(Displays MSB 4digits of
DriveProgramming execution result)
––d026 User Monitor 1
d027 User Monitor 2