7 Detailed Functions
7 - 10
High-function General-purpose Inverter 3G3RX-V1 User’s Manual (I578-E1)
Use this function to monitor the total pulse count of the pulse counter (74: PCNT), which is allocated to
one of the Multi-function Input S1 to S8 Selection (C001 to C008).
Use this function to monitor the position command value in the absolute position control mode.
• This monitor value is displayed only when the V2 Control Mode Selection (P012) is set to 02 or
03 in the sensor vector control mode.
• When the V2 Control Mode Selection (P012) is set to 03 (High-resolution absolute position
control mode), the current position is controlled based on the quadrupled (x4) pulse count
used in internal calculations.
Use this function to monitor the position command value in the absolute position control mode.
• This monitor value is displayed only when the V2 Control Mode Selection (P012) is set to 02 or
03 in the sensor vector control mode.
• When the V2 Control Mode Selection (P012) is set to 03 (High-resolution absolute position
control mode), the current position is controlled based on the quadrupled (x4) pulse count
used in internal calculations.
Pulse Counter Monitor [d028]
Parameter No. Function name Data Default data Unit
d028 Pulse Counter Monitor 0 to 2147483647 (Displays MSB 4 digits) – –
Position Command Monitor (Absolute Position Control Mode) [d029]
Parameter No. Function name Data Default data Unit
d029
Position Command
Monitor
–268435455 to 268435455
(P012 = 02)
–1073741823 to 1073741823
(P012 = 03)
Displays MSB 4digit (1 digit for “–”)
––
Current Position Monitor (Absolute Position Control Mode) [d030]
Parameter No. Function name Data Default data Unit
d030 Current Position Monitor
–268435455 to 268435455
(P012 = 02)
–1073741823 to 1073741823
(P012 = 03)
Displays MSB 4digit (1 digit for “–”)
––