8 Communications Functions
8 - 32
High-function General-purpose Inverter 3G3RX-V1 User’s Manual (I578-E1)
Note 1 The inverter’s rated current is 1,000.
2 When the set value is 10,000 (100.0 s) or more, the value in the second decimal place is ignored.
3 The time information used for register No. 0051 hex to 006C hex is enabled when the LCD Operator is connected.
Register
No.
Modbus
register
spec. No.
Function name
Parameter
No.
R/W Monitor or setting data
Resolution
0058 hex 0057 hex
Fault Monitor 2 Detection
Date
d082 R
Time (o’clock and minutes) at
which error was detected
(Enabled when LCD Digital
Operator is connected)
BCD
0059 to
005A hex
0058 to
0059 hex
Not used
005B hex 005A hex
Fault Monitor 3 Detection
Year
d083 R
Year in which error was detected
(Enabled when LCD Digital
Operator is connected)
BCD
005C hex 005B hex
Fault Monitor 3 Detection
Date
d083 R
Date (month and day) at which
error was detected
(Enabled when LCD Digital
Operator is connected)
BCD
005D hex 005C hex
Fault Monitor 3 Detection
Date
d083 R
Time (o’clock and minutes) at
which error was detected
(Enabled when LCD Digital
Operator is connected)
BCD
005E to
005F hex
005D to
005E hex
Not used
0060 hex 005F hex
Fault Monitor 4 Detection
Year
d084 R
Year in which error was detected
(Enabled when LCD Digital
Operator is connected)
BCD
0061 hex 0060 hex
Fault Monitor 4 Detection
Date
d084 R
Date (month and day) at which
error was detected
(Enabled when LCD Digital
Operator is connected)
BCD
0062 hex 0061 hex
Fault Monitor 4 Detection
Date
d084 R
Time (o’clock and minutes) at
which error was detected
(Enabled when LCD Digital
Operator is connected)
BCD
0063 to
0064 hex
0062 to
0063 hex
Not used
0065 hex 0064 hex
Fault Monitor 5 Detection
Year
d085 R
Year in which error was detected
(Enabled when LCD Digital
Operator is connected)
BCD
0066 hex 0065 hex
Fault Monitor 5 Detection
Date
d085 R
Date (month and day) at which
error was detected
(Enabled when LCD Digital
Operator is connected)
BCD
0067 hex 0066 hex
Fault Monitor 5 Detection
Date
d085 R
Time (o’clock and minutes) at
which error was detected
(Enabled when LCD Digital
Operator is connected)
BCD
0
068 to
0069 hex
0067 to
0068 hex
Not used