Displaying measured values in graphs
ZW-7000/5000
User's Manual
99
3
Basic Operation
4
Set the trigger condition.
• When the trigger target is “Data slope”
• When the trigger target is “Data wind
ow (In)”
• When the trigger target is “Data window (out)”
• When the trigger target is “I/O”
Item Setting item Range Description
Trigger condition Condition = When the measurement results are the same value as the
judgment value, the trigger condition is considered to have
been met.
≠ When the measurement results are a different value from
the judgment v
alue, the trigger condition is considered to
have been met.
> When the measurement results are greater than the
judg
ment v
alue, the trigger condition is considered to have
been met.
≥ When the measurement results are greater than or equal to
the judgment v
alue, the trigger condition is considered to
have been met.
< When the measurement results are less than the judgment
value
, the trigger condition is considered to have been met.
≤ When the measurement results are less than or equal to
the judgment v
alue, the trigger condition is considered to
have been met.
Judgment -999.999999 to
999.99999
9 mm
This is the judgment value for the measurement results.
Item Setting item Range Description
Trigger condition Judgment value
1
-999.999999 to
999.999999 [mm]
When the measurement results are greater than or equal to
judgment value 1 and less than or equal to judgment value
2, the trigger condition is considered to have been met.
Judgment value
2
-999.999999 to
999.99999
9 [mm]
Item Setting item Range Description
Trigger condition Judgment value
1
-999.999999 to
999.999999 [mm]
When the measurement results are less than judgment
value 1 or greater than judgment value 2, the trigger
condition is considered to have been met.
Judgment value
2
-999.999999 to
999.99999
9 [mm]
Item Setting item Range Description
Trigger condition Condition TRUE (rising) When the I/O signal rises, the trigger condition is
considered to have been met.
False (falling) When the I/O signal falls, the trigger condition is considered
to ha
ve been met.