Saving measured values in a file
102
ZW-7000/5000
User's Manual
TriggerStartObject OUT1
OUT2
OUT3
OUT4
TIMING
ZERO
BUSY
ENABLE
HIGH
PAS S
LOW
TASKSTAT
LOGGING
LOGSTAT
LOGERR
STABILITY
RESET
BUFFER_ERR
Indicates the target data for the trigger start condition.
TriggerStartConditions EqualTo
NotEqualTo
AndMore
MoreThan
LessThan
AndLess
True (rising)
False (falling)
Indicates the trigger start condition.
EqualTo: =
NotEqualTo: ≠
AndMore: ≥
MoreThan: >
LessThan: <
AndLess: ≤
Tr ue: R i sin g
False: Falling
TriggerStartValue1 -999.999999 to 999.999999 mm Indicates the judgment value for the trigger start condition.
For data window (in/out), indicates the lower limit.
TriggerStartValue2 -999.999999 to 999.999999 mm Indicates the judgment value for the trigger start condition.
For data window (in/out), indicates the upper limit.
TriggerStartDelay -999.999999 to 999.999999 mm Indicates the delay time for the trigger start condition.
TriggerEnd Tru e
False
Indicates whether the trigger end condition is “Enabled” or
“Disabled”.
TriggerEndType IO
DataSlope
DataWindowIn
DataWindowOut
DataSize
Indicates the trigger end condition.
IO: I/O result
DataSlope: Data slope
DataWindowIn: Data window (in)
DataWindowOut: Data window (out)
DataSize: Number of data points
TriggerEndObject OUT1
OUT2
OUT3
OUT4
TIMING
ZERO
BUSY
ENABLE
HIGH
PAS S
LOW
TASKSTAT
LOGGING
LOGSTAT
LOGERR
STABILITY
RESET
BUFFER_ERR
Indicates the target data for the trigger end condition.
TriggerEndConditions EqualTo
NotEqualTo
AndMore
MoreThan
LessThan
AndLess
True (rising)
False (falling)
Indicates the trigger end condition.
EqualTo: =
NotEqualTo: ≠
AndMore: ≥
MoreThan: >
LessThan: <
AndLess: ≤
Tr ue: R i sin g
False: Falling
TriggerEndValue1 -999.999999 to 999.999999 mm Indicates the judgment value for the trigger end condition.
For data window (in/out), indicates the lower limit.
Item Output items Description