Setting Threshold Value
158
ZW-7000/5000
User's Manual
Multi View Explore : [BankGroup] | [(Bank Data Name)] (double click)
→ Edit pane : [Task Settings] icon ( )
→ Task settings window : [Judgment]
• Hysteresis (hysteresis width) can also be set to threshold values. Set hysteresis when measured values are
dispersed around a threshold value, and judgments are unstable, to prevent chattering.
“2-1 Parallel I/O connection” described in Displacement Sensor ZW-7000 series Confocal Fiber Type
Displacement Sensor User’s Manual for Communications Settings (Z363)
• Threshold values can also be adjusted by directly entering values in the RUN mode.
This helps you to make fine adjustments without shutting down the system.
Changing Threshold Values p.205
Item Setting item Setting value Description
Judgment LOW threshold - 999.999999 to 999.999999 [mm]
Factory default differs depending on the con-
nected Sensor Head.
Set the lower limit (LOW) threshold value.
HIGH threshold - 999.999999 to 999.999999 [mm] Set the upper limit (HIGH) threshold value.
1
Enter the [LOW threshold] and [HIGH thresh-
old].
Threshold Value Settings can also be set by the operating keys on the Sensor Controller.
7-10 Setting Threshold Value p.239
Important
Note