Functions and Operations during Measurement
ZW-7000/5000
User's Manual
205
Sensor controller operations
7
Changing Threshold Values
The threshold value for the task displayed on the main display in the RUN mode can be changed.
To change the target task, change the task displayed on the main display.
Changing Display Details p.204
As an example, here is an explanation of the procedure for setting the HIGH threshold value by entering
“1.000” directl
y.
Operating procedure
Steps Key operation Display Description
1 Press the key in the RUN mode to display the setting
menu.
2 Press the / key to select H.JUDGE, then press the
key.
3 Set “1.000” as the HIGH threshold value.
The current measured value is displayed on the main display and the
current
set threshold value is displayed on the sub-display. (At this
time, the THRESHOLD-H indicator lights up.)
Press key to enter the editing mode, and the sub-display
blinks.
To edit numerical values, use the / / / keys.
Input “1.000”, then press the
key.
4 Press the key to leave the setting menu.
Important