Functions and Operations during Measurement
204
ZW-7000/5000
User's Manual
Changing Display Details
The measurement result displayed on the main display in RUN mode can be selected from TASK1 to 4.
The number of digits displayed can also be changed.
As an example, here is an explanation of the procedure for setting TASK2 as the task to be displayed target.
Operating procedure
Setting [DISPLAY] Option [DISPLAY]
Task for displayed target [DISP] TASK1/TASK2/TASK3/TASK4
Decimal point digit [DEC.NUM] 0 [0DIG]/1 [1DIG]/2 [2DIG]/3 [3DIG]/4 [4DIG]/5 [5DIG]
Steps Key operation Display Description
1 Press the key in the RUN mode to display the setting
menu.
2 Press the / keys to select “DISP” and press the key.
3 Select the task to be the displayed target.
The current setting value is displayed on the sub-display.
Press / key to enter editing mode and the sub-display blinks.
Select “TASK2” and press the
key.
4 Press the key to leave the setting menu.