Functions and Operations during Measurement
ZW-7000/5000
User's Manual
203
Sensor controller operations
7
Details Displayed on the Sub-display
The items listed in the following table appears on the sub-display.
Press the / keys to toggle the display.
Display Details Description
Threshold Displays the HIGH and LOW threshold values for tasks for displayed target.
THRESHOLD-H indicator lights for the HIGH threshold value. THRESHOLD-L indicator lights for the LOW
threshold value.
Analog output Displays the voltage or current value output in analog format.
The display details for the output destination setting are different for voltage output and for current output.
(Values displayed here are reference values only. These values differ from actual analog output values.)
Judgment result The judgment result for each task appears.
The TASK1, 2, 3 and 4 judgment results are displayed starting from the left.
H: HIGH
P: PASS
L: LOW
E: ERROR
Resolution Displays the fluctuation width (peak to peak) of the measured value over a fixed amount of time.
Amount of emitted light Displays the current amount of emitted light.
The time is displayed in the range 0.01 to 100.00 %.
Distance Displays the distance from the Sensor Head to a target to measure.
Effective bank Displays the current bank number.
Displayed task Displays the currently selected task number from TASK1 to TASK4.
The measured value for the selected task appears on the main display.
Ethernet communication
status
Whether Ethernet communications are possible is displayed.
ONLINE: Communication possible
OFLINE: Communication not possible
Ethernet link status Whether the Ethernet connection is enabled is displayed.
LINK.OK: Connection established
LINK.--: Connection not established
Tag link status The status of EtherNet/IP tag link communication is displayed.
TAG.INI: Initializing
TAG.OK: Tag connection established
TAG.--: Tag connection not established
TAG.ER1: Tag link abnormality
TAG.ER2: Other abnormality
Internal logging status Displays the status of operation internal logging.
LOG.RDY : Internal logging stopped state (When ZW start, When internal logging data is cleared, When
inte
rnal logging stopped)
LOG.RUN : Internal logging in progress
LOG.END : Internal logging ended state(When internal logging is automatically ended)
Peak amount of received
light
Displays the current peak amount of received light. They are shown within the range of 0 to 4095.