Search from Menu Tree
192
ZW-7000/5000
User's Manual
Setting Option/Setting Range Pages
Measurement
setting
[MEAS]
T
ASK1
[TASK1]
Threshold
[JUDGE]
Teaching
[TEACH]
High
threshold
[H.JUDGE]
-999.999999 to 999.999999 mm
(default value: +25% of measuring
range)
p.239
(cont'd) (cont'd) Low threshold
[L.JUDGE]
-999.999999 to 999.999999 mm
(default value: -25% of measuring
range)
Direct
[DIRECT]
High
threshold
[H.JUDGE]
-999.999999 to 999.999999 mm
(default value: +25% of measuring
range)
p.241
Low threshold
[L.JUDGE]
-999.999999 to 999.999999 mm
(default value: -25% of measuring
range)
TASK2
[TASK2]
(Same content as TASK1)
Default value of measurement item is [NONE]
TASK3
[TASK3]
(Same content as TASK1)
Default value of measurement item is [NONE]
TASK4
[TASK4]
(Same content as TASK1)
Default value of measurement item is [NONE]
I/O setting
[I/O]
Non-measurement
setting
[HLD.RST]
Non-measurement
setting
[HLD.RST]
Keep [KEEP]/Clamp [CLAMP]*
*1
Judgment
[JUDGE]
Output target
[OUTPUT]
Output target
[OUTPUT]
TASK1 [TASK1]*/TASK2 [TASK2]/
TASK3 [TASK3]/TASK4 [TASK4]
*1
Hysteresis
[HYS]
Hysteresis
[HYS]
0 to 99.9999 mm
(default value: 0.05% of measuring
range)
*1
Timer
[TIMER]
TIMER
*2
[TIMER]
Off* [OFF]/Off delay [OFF.DLY]/
On delay [ONDLY]/One shot [1SHOT]
*1
Timer time
[TIME]
0.2 to 5000 ms (default value: 0.2)
Digital output
[DIGTAL]
Output data 1
[OUT1]
OFF[OFF] / TASK1 [TASK1]* / TASK2
[TASK2] / TASK3 [TASK3] / TASK4
[TASK4] / Amount of emitted light [LIGHT]
/ Peak amount of received light (Exposure
control edge) [PEAK.CT] / Peak amount
of received light (1st surface) [PEAK.1] /
Peak amount of received light (2nd
surface) [PEAK.2] / Peak amount of
received light (3rd surface) [PEAK.3] /
Peak amount of received light (4th
surface) [PEAK.4]
*1
Output data 2
[OUT2]
OFF[OFF] / TASK1 [TASK1] / TASK2
[TASK2]* / TASK3 [TASK3] / TASK4
[TASK4] / Amount of emitted light [LIGHT]
/ Peak amount of received light (Exposure
control edge) [PEAK.CT] / Peak amount
of received light (1st surface) [PEAK.1] /
Peak amount of received light (2nd
surface) [PEAK.2] / Peak amount of
received light (3rd surface) [PEAK.3] /
Peak amount of received light (4th
surface) [PEAK.4]
*1
Output data 3
[OUT3]
OFF[OFF] / TASK1 [TASK1] / TASK2
[TASK2] / TASK3 [TASK3]* / TASK4
[TASK4] /Amount of emitted light [LIGHT]
/ Peak amount of received light (Exposure
control edge) [PEAK.CT] / Peak amount
of received light (1st surface) [PEAK.1] /
Peak amount of received light (2nd
surface) [PEAK.2] / Peak amount of
received light (3rd surface) [PEAK.3] /
Peak amount of received light (4th
surface) [PEAK.4]
*1
Output data 4
[OUT4]
OFF[OFF] / TASK1 [TASK1] / TASK2
[TASK2] / TASK3 [TASK3] / TASK4
[TASK4]* / Amount of emitted light
[LIGHT] / Peak amount of received light
(Exposure control edge) [PEAK.CT] /
Peak amount of received light (1st
surface) [PEAK.1] / Peak amount of
received light (2nd surface) [PEAK.2] /
Peak amount of received light (3rd
surface) [PEAK.3] / Peak amount of
received light (4th surface) [PEAK.4]
*1
*1. For more detail, refer to the following.
2-1 Connecting Parallel I/O in Confocal Fiber Type Displacement Sensor
User's Manual for Communications Settings (Cat.
No.Z363).
*2. Only [OFF] is allowable in Ext
er
nal/PDO synchronized mode.