Wiring
70
ZW-7000/5000
User's Manual
Class Name Description
Parallel
output
HIGH output This outputs judgment results - HIGH (HIGH threshold values < Measured value).
PASS output This outputs judgment results - PASS (LOW threshold values Measured value HIGH
thresho
ld values).
LOW output This outputs judgment results - LOW (LOW threshold values > Measured value).
ALARM output This turns ON when there is a system error.
BUSY output This turns ON during sampling with the hold f
unction
enabled. It allows you to check
whether or not the self-trigger is functioning correctly.
It also turns ON during bank switching.
ENABLE output This turns ON when the sensor is ready for measurement.
This output is interlocked with the ENABLE indicator.
BANK_OUT output This outputs the currently specified bank number.
It expresses the bank number in combinations of BANK_OUT1, 2 and 3.
SYNCFLG/TRIGBUSY
out
put
In
the internal/PDO synchronized mode, this output operates as SYNCFLG. This turns ON
when measurement synchronization processing is executed by SYNC input and the state
changes to one where normal measurement values can be output.
In the external synchronous measurement mode,
th
is output operates as TRIGBUSY. This
turns ON while a measurement by TRIG input is being performed. The next TRIG input
cannot be turned ON until this turns OFF.
STABILITY output This turns ON when 1surface is within the measurement range.
This output is interlocked with the STABILITY indicator.
LOGSTAT output This turns ON while internal logging is in execution.
LOGERR output This turns ON when internal logging fails. Turns ON when the logging results is saved the
maximum
number, retry to execute the inside logging. If the LOGGING signal turns OFF,
LOGERR signal is also turned OFF.
TASKSTAT output This turns ON when the measurement value is finalized.
In FUNC mode, output of each signals are the followings;
• BUSY output Turns ON
• BANK_OUT Outputs the current bank number
• Other signals Turns OFF
Bank Number BANK_OUT1 BANK_OUT2 BANK_OUT3
BANK1 OFF OFF OFF
BANK2 ON OFF OFF
BANK3 OFF ON OFF
BANK4 ON ON OFF
BANK5 OFF OFF ON
BANK6 ON OFF ON
BANK7 OFF ON ON
BANK8 ON ON ON