Command reference
R&S
®
ZNL/ZNLE
1002User Manual 1178.5966.02 ─ 20
SYSTem:COMMunicate:GPIB[:SELF]:INIT:WAIT.............................................................1003
SYSTem:COMMunicate:GPIB[:SELF]:LPORt:ALIGn........................................................1003
SYSTem:COMMunicate:NET:HOSTname....................................................................... 1004
SYSTem:COMMunicate:RDEVice:AKAL:ADDRess..........................................................1004
SYSTem:COMMunicate:RDEVice:AKAL:ADDRess:ALL?................................................. 1004
SYSTem:COMMunicate:RDEVice:AKAL:ADDRess:SUBModule:ALL?............................... 1005
SYSTem:COMMunicate:RDEVice:AKAL:CKIT.................................................................1005
SYSTem:COMMunicate:RDEVice:AKAL:CKIT:CATalog?.................................................. 1006
SYSTem:COMMunicate:RDEVice:AKAL:CKIT:STANdard:CATalog?.................................. 1007
SYSTem:COMMunicate:RDEVice:AKAL:DATE?..............................................................1007
SYSTem:COMMunicate:RDEVice:AKAL:FRANge?..........................................................1007
SYSTem:COMMunicate:RDEVice:AKAL:PORTs?............................................................1008
SYSTem:COMMunicate:RDEVice:AKAL:PREDuction[:STATe].......................................... 1008
SYSTem:COMMunicate:RDEVice:AKAL:SDATa?............................................................ 1009
SYSTem:COMMunicate:RDEVice:AKAL:WARMup[:STATe]?.............................................1009
SYSTem:COMMunicate:RDEVice:PMETer<Pmtr>:AZERo................................................1010
SYSTem:COMMunicate:RDEVice:PMETer:CATalog?.......................................................1010
SYSTem:COMMunicate:RDEVice:PMETer:CONFigure:AUTO[:STATe]...............................1010
SYSTem:COMMunicate:RDEVice:PMETer:COUNt?.........................................................1011
SYSTem:COMMunicate:RDEVice:PMETer<Pmtr>:DEFine................................................1011
SYSTem:COMMunicate:RDEVice:PMETer:DELete..........................................................1012
SYSTem:COMMunicate:RDEVice:PMETer<Pmtr>:SPCorrection[:STATe]...........................1012
SYSTem:COMMunicate:AKAL:CONNection <CalStandard>, <Port>[,
<SecondPort>[, <CalkitIndex>]]
Connects the selected calibration standard to one or two ports of the active calibration
unit (see SYSTem:COMMunicate:RDEVice:AKAL:ADDRess).
Setting parameters:
<CalStandard> THRough | OPEN | SHORt | MATCh
Connected one or two-port standard
<Port> Port number of the calibration unit, for one and two-port stand-
ards.
<SecondPort> Second port number of the calibration unit.
For two-port standards (THRough) this parameter must be provi-
ded, for one-port standards (OPEN | SHORt | MATCh) it must be
omitted.
<CalkitIndex> For calibration units that are equipped with more than one cali-
bration kit, this parameter indicates the 1-based index of the cal
kit to be used (mandatory!).
For other calibration units, this parameter is optional, but if it is
provided, it must be set to 1.
Example:
SYST:COMM:AKAL:CONN THR, 1, 2
Connect a through standard between ports 1 and 2 of the cal
unit.
Usage: Setting only