(3) Processing flow (in single-reception mode)
Figure 14 - 60 Timing Chart of Slave Reception (in Single-Reception Mode)
(Type 1: DAPmn = 0, CKPmn = 0)
Receive data 3
Reception & shift operation
Reception & shift operation
Reception & shift operation
SSmn
SEmn
SDRmn
STmn
SCKp pin
SIp pin
Shift register mn
INTCSIp
TSFmn
Data receptionData receptionData reception
Receive data 3Receive data 2Receive data 1
Receive data 2Receive data 1
Read
Read Read