RL78/G1H CHAPTER 24 SAFETY FUNCTIONS
R01UH0575EJ0120 Rev. 1.20 Page 784 of 920
Dec 22, 2016
Figure 24 - 8 RAM Parity Error Check Flow
Note See CHAPTER 21 RESET FUNCTION for details on how to confirm internal resets due to RAM parity errors.
Confirm that a parity
error has occurred.
RPERF = 1
Note
No
RAM check
Parity error has
occurred
RPERDIS = 1
RAM check
RPEF = 1
RPERDIS = 0
Yes
No
Enable parity error
resets
Disable parity error resets
Read RAM
Yes
No
Yes
Check start
Generation of
internal reset
Normal operation
RAM failure
processing