RL78/G1H CHAPTER 31 ELECTRICAL SPECIFICATIONS
R01UH0575EJ0120 Rev. 1.20 Page 899 of 920
Dec 22, 2016
31.7.2.2 Compatible with ARIB Standard
XIN frequency accuracy is required according to the table below to satisfy the ARIB standard.
Frequency
band
[MHz]
Maximum
frequency
[MHz]
Symbol rate
[ksymbols/s]
Variable
index
MIN. TYP. MAX. Unit
920 928 50 1 ‒20 — +20 ppm
928 100 1 ‒20 — +20 ppm
928 200 1 ‒20 — +20 ppm
928 200 0.33 ‒20 — +20 ppm