Remote Control Commands
R&S
®
SMBV100A
798Operating Manual 1176.8016.02 ─ 17
SOURce:PULM:STATe 1
OUTPut1:STATe 1
[:SOURce<hw>]:PULM:DELay........................................................................................ 798
[:SOURce<hw>]:PULM:DOUBle:DELay............................................................................798
[:SOURce<hw>]:PULM:DOUBle:STATe........................................................................... 799
[:SOURce<hw>]:PULM:DOUBle:WIDTh........................................................................... 799
[:SOURce<hw>]:PULM:MODE........................................................................................ 799
[:SOURce<hw>]:PULM:OUTPut:SYNC[:STATe]................................................................799
[:SOURce<hw>]:PULM:PERiod....................................................................................... 800
[:SOURce<hw>]:PULM:POLarity..................................................................................... 800
[:SOURce<hw>]:PULM:SOURce..................................................................................... 801
[:SOURce<hw>]:PULM:STATe........................................................................................801
[:SOURce<hw>]:PULM:TRIGger:EXTernal:GATE:POLarity................................................ 801
[:SOURce<hw>]:PULM:TRIGger:EXTernal:IMPedance......................................................802
[:SOURce<hw>]:PULM:TRIGger:EXTernal:SLOPe............................................................802
[:SOURce<hw>]:PULM:TRIGger:MODE........................................................................... 802
[:SOURce<hw>]:PULM:WIDTh........................................................................................803
[:SOURce<hw>]:PULM:DELay <Delay>
Sets the pulse delay.
Parameters:
<Delay> float
Range: 0 to 100 s
Increment: 10 ns
*RST: 10 ns
Example:
PULM:DEL 13 us
13 us elapse after a trigger before the first pulse is generated.
Options: R&S R&S SMBV-K23 (Pulse Generator)
Manual operation: See " Pulse Delay - Pulse Generator " on page 271
[:SOURce<hw>]:PULM:DOUBle:DELay <Delay>
Sets the delay from the start of the first pulse to the start of the second pulse.
Parameters:
<Delay> float
Range: 10 ns to 100 s
Increment: 5 ns
*RST: 3 us
Example:
PULM:DOUB:DEL 22 us
22 us elapse between the beginning of the first pulse and the
beginning of the second pulse in double-pulse mode.
Options: R&S SMBV-K23 (Pulse Generator)
Manual operation: See " Double Pulse Delay - Pulse Generator " on page 271
SOURce Subsystem