This example shows how to set up a frequency sweep.
1. Set the sweep range.
SOUR:FREQ:CENT 200 MHz
SOUR:FREQ:SPAN 300 MHz
2. Select linear or logarithmic spacing.
SOUR:SWE:FREQ:SPAC LIN
3. Set the step width and dwell time.
SOUR:SWE:FREQ:STEP:LIN 20 MHz
SOUR:SWE:FREQ:DWEL 12 ms
4. Select the trigger mode.
TRIG:FSW:SOUR SING
5. Select the sweep mode and activate the sweep.
SOUR:SWE:FREQ:MODE AUTO
SOUR:FREQ:MODE SWE
6. Trigger the sweep.
SOURce:SWE:FREQ:EXEC
It is recommended that you switch off the "Start/Stop Display Update" for optimum
sweep performance, especially with short dwell times (SYST:DISP:UPD OFF).
[:SOURce<hw>]:SWEep[:FREQuency]:DWELl..................................................................807
[:SOURce<hw>]:SWEep[:FREQuency]:EXECute.............................................................. 808
[:SOURce<hw>]:SWEep[:FREQuency]:MODE.................................................................. 808
[:SOURce<hw>]:SWEep[:FREQuency]:POINts................................................................. 809
[:SOURce<hw>]:SWEep[:FREQuency]:RETRace..............................................................810
[:SOURce<hw>]:SWEep[:FREQuency]:RUNNing?............................................................ 810
[:SOURce<hw>]:SWEep[:FREQuency]:SHAPe................................................................. 810
[:SOURce<hw>]:SWEep[:FREQuency]:SPACing...............................................................811
[:SOURce<hw>]:SWEep[:FREQuency]:STEP[:LINear].......................................................811
[:SOURce<hw>]:SWEep[:FREQuency]:STEP:LOGarithmic................................................ 812
[:SOURce<hw>]:SWEep:POWer:DATTenuator:STATe...................................................... 813
[:SOURce<hw>]:SWEep:POWer:DWELl.......................................................................... 813
[:SOURce<hw>]:SWEep:POWer:EXECute....................................................................... 813
[:SOURce<hw>]:SWEep:POWer:MODE...........................................................................814
[:SOURce<hw>]:SWEep:POWer:POINts.......................................................................... 814
[:SOURce<hw>]:SWEep:POWer:RETRace.......................................................................815
[:SOURce<hw>]:SWEep:POWer:RUNNing?..................................................................... 815
[:SOURce<hw>]:SWEep:POWer:SHAPe..........................................................................815
[:SOURce<hw>]:SWEep:POWer:SPACing:MODE?........................................................... 816
[:SOURce<hw>]:SWEep:POWer:STEP[:LOGarithmic]....................................................... 816
[:SOURce<hw>]:SWEep:RESet[:ALL].............................................................................. 817
[:SOURce<hw>]:SWEep[:FREQuency]:DWELl <Dwell>
Sets the time taken for each frequency step of the sweep.