Captive Portal for Guest Access
13.4 Configuring Internal Captive Portal for Guest Network
SCALANCE W1750D UI
Configuration Manual, 02/2018, C79000-G8976-C451-02
175
(scalance)# commit apply
To configure internal captive portal for a wired profile:
(scalance)(config)# wired-port-profile <name>
(scalance)(wired ap profile <name>)# type <guest>
(scalance)(wired ap profile <name>)# captive-portal {<internal-
authenticated>|<internal- acknowledged>} exclude-uplink {3G|4G|Wifi|Ethernet}
(scalance)(wired ap profile <name>)# mac-authentication
(scalance)(wired ap profile <name>)# auth-server <server1>
(scalance)(wired ap profile <name>)# radius-reauth-interval <Minutes>
(scalance)(wired ap profile <name>)# end
(scalance)# commit apply
To customize internal captive portal splash page:
(scalance)(config)# wlan captive-portal
(scalance)(Captive Portal)# authenticated
(scalance)(Captive Portal)# background-color <color-indicator>
(scalance)(Captive Portal)# banner-color <color-indicator>
(scalance)(Captive Portal)# banner-text <text>
(scalance)(Captive Portal)# decoded-texts <text>
(scalance)(Captive Portal)# redirect-url <url>
(scalance)(Captive Portal)# terms-of-use <text>
(scalance)(Captive Portal)# use-policy <text>
(scalance)(Captive Portal)# end
(scalance)# commit apply
To upload a customized logo from a TFTP server to the AP:
(scalance)# copy config tftp <ip-address> <filename> portal logo