Roles and Policies
15.2 Content Filtering
SCALANCE W1750D UI
Configuration Manual, 02/2018, C79000-G8976-C451-02
265
Configuring ACL Rules to Redirect Blocked HTTPS Websites to a Custom Blocked Page
URL
Note
Before you configure an ACL rule for a specific WLAN SSID or Wired pr
ofile to redirect
HTTPS websites to a custom error page, you must ensure that the Blocked Page URL rule is
configured for the HTTP websites blocked for the same WLAN SSID or Wired profile. In this
scenario, all the blocked HTTP and HTTPS websites will be r
edirected to the custom error
page URL.
To redirect blocked HTTPS websites to a custom error page URL
In the SCALANCE W UI
1. Navigate to
Security > Roles
.
2. Select any WLAN SSID or Wired profile role, and click
New
in the Access Rules section.
3. In the
New Rule
window, select the rule type as
Redirect Blocked HTTPS
.
4. Click
OK
.
5. Click
OK
in the
Roles
tab to save the changes
In the CLI
To configure an ACL rule to redirect blocked HTTPS to a custom error page URL:
(scalance)(config)# wlan access-rule <access_rule_name>
(scalance) (Access Rule "<access_rule_name>")# dpi-error-page-url <idx>
(scalance) (Access Rule "<access_rule_name>")# redirect-blocked-https-traffic
(scalance) (Access Rule "<access_rule_name>")# end
(scalance)# commit apply

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W1750D UI and is the answer not in the manual?

Siemens SCALANCE W1750D UI Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W1750D UI
CategoryWireless Access Point
LanguageEnglish

Related product manuals