Setting up an AP
4.4 Accessing the SCALANCE W CLI
SCALANCE W1750D UI
Configuration Manual, 02/2018, C79000-G8976-C451-02
37
Applying Configuration Changes
Each command processed by the VC is applied on all the slaves in a cluster. The changes
configured in a CLI session are saved in the CLI context. The CLI does not support the
configuration data exceeding the 4K buffer size in a CLI session. Therefore, Siemens
recommends that you configure fewer changes at a time and apply the changes at regular
intervals.
To apply and save the configuration changes at regular intervals, execute the following
command in the privileged EXEC mode:
(scalance)# commit apply
To apply the configuration changes to the cluster without saving the configuration, execute
the following command in the privileged EXEC mode:
(scalance)# commit apply no-save
To view the changes that are yet to be applied, execute the following command in the
privileged EXEC mode:
(scalance)# show uncommitted-config
To revert to the earlier configuration, execute the following command in the privileged EXEC
mode.
(scalance)# commit revert
Example:To apply and view the configuration changes:
(scalance)(config)# rf dot11a-radio-profile
(scalance)(RF dot11a Radio Profile)# beacon-interval 200
(scalance)(RF dot11a Radio Profile)# no legacy-mode
(scalance)(RF dot11a Radio Profile)# dot11h
(scalance)(RF dot11a Radio Profile)# interference-immunity 3
(scalance)(RF dot11a Radio Profile)# csa-count 2
(scalance)(RF dot11a Radio Profile)# spectrum-monitor
(scalance)(RF dot11a Radio Profile)# end

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W1750D UI and is the answer not in the manual?

Siemens SCALANCE W1750D UI Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W1750D UI
CategoryWireless Access Point
LanguageEnglish

Related product manuals