Setting up an AP
4.4 Accessing the SCALANCE W CLI
SCALANCE W1750D UI
38 Configuration Manual, 02/2018, C79000-G8976-C451-02
(scalance)# show uncommitted-config
rf dot11a-radio-profile
beacon-interval 200
no legacy-mode
dot11h
interference-immunity 3
csa-count 2
spectrum-monitor
(scalance)# commit apply
Using Sequence-Sensitive Commands
The SCALANCE W CLI does not support positioning or precedence of sequence-sensitive
commands. Therefore, Siemens recommends that you remove the existing configuration
before adding or modifying the configuration details for sequence-sensitive commands. You
can either delete an existing profile or remove a specific configuration by using the
commands.
The following table lists the sequence-sensitive commands and the corresponding
commands to remove the configuration:
Sequence-Sensitive Command
opendns <username <password>
rule <dest> <mask> <match> <protocol> <start-port>
<end-port> {permit | deny | src-nat | dst-nat
{<IP- address> <port> |
<port>}}[<option1....option9>]
no rule <dest> <mask> <match>
<protocol> <start-port> <end-port>
{permit | deny | src-nat | dst-nat}
mgmt-auth-server <auth-profile-name>
no mgmt-auth-server <auth-profile- name>
set-role <attribute>{{equals| not-equals | starts-
with | ends-with | contains} <operator> <role> |
value-of}
no set-role <attribute>{{equals |
not-equals | starts-with | ends-with
| contains} <operator>| value-of} no set-role
set-vlan <attribute>{{equals | not-equals |
starts- with | ends-with | contains} <operator>
<VLAN-ID> | value-of}
no set-vlan <attribute>{{equals |
not-equals | starts-with | ends-with
| contains} <operator> | value-of} no set-vlan