Hotspot Profiles
33.2 Configuring Hotspot Profiles
SCALANCE W1750D UI
508 Configuration Manual, 02/2018, C79000-G8976-C451-02
(scalance)(connection-capabilities <name>)# udp-voip
(scalance)(connection-capabilities <name>)# enable
(scalance)(connection-capabilities <name>)# end
(scalance)# commit apply
Configuring an Operating-Class Profile
You can configure an operating-class profile to list the channels on which the hotspot is
capable of operating. To configure an H2QP operating-class profile:
(scalance)(config) # hotspot h2qp-oper-class-profile <name>
(scalance)(operator-class <name>)# op-class <class-ID>
(scalance)(operator-class <name>)# enable
(scalance)(operator-class <name>)# end
(scalance)# commit apply
Configuring a WAN Metrics Profile
You can configure a WAN metrics profile to define information about access network
characteristics such as link status and metrics.
To configure a WAN metrics profile:
(scalance)(config)# hotspot h2qp-wan-metrics-profile <name>
(scalance)(WAN-metrics <name>)# at-capacity
(scalance)(WAN-metrics <name>)# downlink-load <load>
(scalance)(WAN-metrics <name>)# downlink-speed <speed>
(scalance)(WAN-metrics <name>)# load-duration <duration>
(scalance)(WAN-metrics <name>)# symm-link
(scalance)(WAN-metrics <name>)# uplink-load <load>
(scalance)(WAN-metrics <name>)# uplink-speed <speed>
(scalance)(WAN-metrics <name>)# wan-metrics-link-status <status>
(scalance)(WAN-metrics <name>)# end
(scalance)# commit apply
You can specify the following WAN downlink and uplink parameters:
Downlink load
Indicates the percentage of the WAN downlink currently utilized. The
default value of 0 indicates that the downlink speed is unknown or unspecified.
Downlink speed
Indicates the WAN downlink speed in Kbps.
Uplink load
Indicates the percentage of the WAN uplink currently utilized. The default
value of 0 indicates that the downlink speed is unknown or unspecified.
Uplink speed
Indicates the WAN uplink speed in Kbps.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W1750D UI and is the answer not in the manual?

Siemens SCALANCE W1750D UI Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W1750D UI
CategoryWireless Access Point
LanguageEnglish

Related product manuals