6 Maintenance
Maintenance
Checking the battery condition, acid
level and acid density
CAUTION
Risk of damage!
Heed the information in the operating instructi-
ons for the battery.
Remove the battery from the truck, see
chapter "Handling the battery".
Inspect battery for cracked housing, raised
plate sand acid leaks.
WARNING
The electrolyte (dilute sulphuric acid) is poisonous
and caustic!
Observe safety regulations for handling battery
acid; see chapter "Battery acid".
Rinse away spilt battery acid immediately with
plenty of water!
Have defective battery overhauled.
6321_003-126
1
2
Open filler cap (1) and check the acid level.
For batteries with "caged cell plugs", the
acid must reach the bottom of the cage; for
batteries without "caged cell plugs", it must
cover the lead plates by about 10–15 mm.
Top up missing fluid with distilled water only.
The battery cell covers must be kept clean and
dry.
Remove any oxidation residues on the
battery terminals and then apply acid-free
grease to the terminals.
Tighten the battery terminals (2).
Check acid density with an acid siphon.
After charging, this value must be between
1.24 and 1.29 kg/l.
32
4 55048011501 EN - 12/2015