You can find more safety system information in the Hardware Installation Manual.
21.2. Setting a Safety Password
You must set a password to Unlock all safety settings that make up your Safety Configuration. If no
safety password is applied, you are prompted to set it up.
1. In your PolyScope header right corner, press the Hamburger menu and select Settings.
2. On the left of the screen, in the blue menu, press Password and select Safety.
3. In New password, type a password.
4. Now, in Confirm new password, type the same password and press Apply.
5. In the bottom left of the blue menu, press Exit to return to previous screen.
You can press the Lock tab to lock all Safety settings again or simply navigate to a screen outside
of the Safety menu.
21.3. Changing the Safety Configuration
Changes to the Safety Configuration settings must comply with the risk assessment conducted by
the integrator (seeHardware Installation Manual ).
Recommended procedure:
UR5e 120 User Manual
21.Safety Configuration
Copyright © 2009–2021 by UniversalRobotsA/S. All rights reserved.