The mains supply is equipped with the following:
•
Connection to ground
•
Main fuse
•
Residual current device
It is recommended to install a main switch to power off all equipment in the robot
application as an easy means for lockout-tagout under service. The electrical
specifications are shown in the table below.
Parameter Min Typ Max Unit
Input voltage 100 - 240 VAC
External mains fuse (@ 100-200V) 8 - 16 A
External mains fuse (@ 200-265V) 8 - 16 A
Input frequency 47 - 440 Hz
Stand-by power - - <1.5 W
Nominal operating power 90 150 325 W
UR5e 46 User Manual
6.Electrical Interface