The device is shipped with a factory default IP address for its operations, administration,
maintenance, and provisioning (OAMP) VoIP LAN interface, as shown in the table below:
Default VoIP OAMP IP Address
IP Address Value
IP Address
Device with single module (trunks 1-8): 10.1.10.11
Device's second module (trunks 9-16): 10.1.10.10
Subnet Mask
255.255.0.0
Default Gateway IP
Address
0.0.0.0
The default IP address can be used for initially accessing the device, using any of its
management tools (i.e., embedded Web server, EMS, or Telnet). Once accessed, you can
change this default IP address to correspond with your networking scheme in which the
device is deployed. After changing the IP address, you can re-access the device with this
new OAMP IP address and start configuring and managing the device as desired.
This section describes the different methods for changing the device's default IP address to
suit your networking environment:
Embedded command line interface (CLI) - see 'CLI' on page 30
Embedded HTTP/S-based Web server - see 'Web Interface' on page 27
Bootstrap Protocol (BootP) - see BootP/TFTP Server on page 29
2.1 Web Interface
The procedure below describes how to assign a new OAMP IP address using the Web
interface.
To assign a new OAMP IP address using the Web interface:
1. Disconnect the network cables (if connected) from the device.
2. Connect one of the Ethernet ports located on the rear panel (labeled ETH) directly to
the network interface of your computer, using a straight-through Ethernet cable.
3. Change the IP address and subnet mask of your computer to correspond with the
default IP address and subnet mask of the device.