Version 6.6 433 Mediant 2000
User's Manual 35. Restoring Factory Defaults
35 Restoring Factory Defaults
You can restore the device's configuration to factory defaults using one of the following
methods:
CLI (see 'Restoring Defaults using CLI' on page 433)
Loading an empty ini file (see 'Restoring Defaults using an ini File' on page 434)
35.1 Restoring Defaults using CLI
The device can be restored to factory defaults using CLI, as described in the procedure
below.
To restore factory defaults using CLI:
1. Establish a Telnet session with the device.
2. At the CLI prompt, type the following command to access the configuration mode, and
then press Enter:
# conf
3. At the prompt, type the following command to reset the device to default settings, and
then press Enter:
/CONFiguration> RestoreFactorySettings
4. At the prompt, type the following command to confirm reset to default settings, and
then press Enter:
/CONFiguration> RestoreFactorySettings APPROVED