User's Manual 30 Document #: LTRT-68822
Mediant 2000
6. Physically reset the device by powering it down and then up again. This enables the
device to receive its new networking parameters through the BootP process.
7. Repeat steps 2 through 6 for the device's second module (if used).
2.3 CLI
The procedure below describes how to assign a new OAMP IP address, using CLI.
 To assign a new OAMP IP address using CLI:
1. Establish a Telnet session with the device using a terminal emulator program (such as
HyperTerminal) with the following communication port settings:
• Baud Rate: 115,200 bps
• Data Bits: 8
• Parity: None
• Stop Bits: 1
• Flow Control: None
2. At the prompt, type the following command to access the configuration folder, and
then press Enter:
conf
3. At the prompt, type the following command to view the current network settings, and
then press Enter:
GCP IP
4. At the prompt, typing the following command to change the network settings, and then
press Enter:
SCP IP <ip_address> <subnet_mask> <default_gateway>
You must enter all three network parameters, each separated by a space, for
example:
SCP IP 10.13.77.7 255.255.0.0 10.13.0.1
5. At the prompt, type the following command to save the settings and reset the device,
and then press Enter:
SAR