6. Physically reset the device by powering it down and then up again. This enables the
device to receive its new networking parameters through the BootP process.
7. Repeat steps 2 through 6 for the device's second module (if used).
2.3 CLI
The procedure below describes how to assign a new OAMP IP address, using CLI.
 To assign a new OAMP IP address using CLI:
1. Establish a Telnet session with the device using a terminal emulator program (such as
HyperTerminal) with the following communication port settings:
• Baud Rate: 115,200 bps
• Data Bits: 8
• Parity: None
• Stop Bits: 1
• Flow Control: None
2. At the prompt, type the following command to access the configuration folder, and
then press Enter:
conf
3. At the prompt, type the following command to view the current network settings, and
then press Enter:
GCP IP
4. At the prompt, typing the following command to change the network settings, and then
press Enter:
SCP IP <ip_address> <subnet_mask> <default_gateway>
You must enter all three network parameters, each separated by a space, for
example:
SCP IP 10.13.77.7 255.255.0.0 10.13.0.1
5. At the prompt, type the following command to save the settings and reset the device,
and then press Enter:
SAR

Table of Contents

Other manuals for AudioCodes Mediant 2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 2000 and is the answer not in the manual?

AudioCodes Mediant 2000 Specifications

General IconGeneral
BrandAudioCodes
ModelMediant 2000
CategoryGateway
LanguageEnglish

Related product manuals