Version 6.6 517 Mediant 2000
User's Manual 45. Configuration Parameters Reference
45.2.3 Telnet Parameters
The Telnet parameters are described in the table below.
Telnet Parameters
Parameter Description
Web: Embedded Telnet
Server
EMS: Server Enable
[TelnetServerEnable]
Enables the device's embedded Telnet server. Telnet is disabled by
default for security.
ï‚§ [0] Disable (default)
ï‚§ [1] Enable Unsecured
ï‚§ [2] Enable Secured (SSL)
Note: Only the primary Web User Account (which has Security
Administration access level) can access the device using Telnet (see
'Configuring Web User Accounts' on page 60).
Web: Telnet Server TCP
Port
EMS: Server Port
[TelnetServerPort]
Defines the port number for the embedded Telnet server.
The valid range is all valid port numbers. The default port is 23.
Web: Telnet Server Idle
Timeout
EMS: Server Idle
Disconnect
[TelnetServerIdleDisconn
ect]
Defines the timeout (in minutes) for disconnection of an idle Telnet
session. When set to zero, idle sessions are not disconnected.
The valid range is any value. The default is 0.
Note: For this parameter to take effect, a device reset is required.
45.2.4 SNMP Parameters
The SNMP parameters are described in the table below.
SNMP Parameters
Parameter Description
Web: Enable SNMP
[DisableSNMP]
Enables SNMP.
ï‚§ [0] Enable = (Default) SNMP is enabled.
ï‚§ [1] Disable = SNMP is disabled and no traps are sent.
[SNMPPort]
Defines the device's local (LAN) UDP port used for SNMP
Get/Set commands.
The range is 100 to 3999. The default port is 161.
Note: For this parameter to take effect, a device reset is required.
EMS: Keep Alive Trap Port
[KeepAliveTrapPort]
Defines the port to which keep-alive traps are sent.
The valid range is 0 - 65534. The default is port 162.
[SendKeepAliveTrap]
Enables keep-alive traps and sends them every 9/10 of the time
as defined by the NATBindingDefaultTimeout parameter.
ï‚§ [0] = Disable
ï‚§ [1] = Enable
Note: For this parameter to take effect, a device reset is required.

Table of Contents

Other manuals for AudioCodes Mediant 2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 2000 and is the answer not in the manual?

AudioCodes Mediant 2000 Specifications

General IconGeneral
BrandAudioCodes
ModelMediant 2000
CategoryGateway
LanguageEnglish

Related product manuals