Version 6.6 679 Mediant 2000
User's Manual 45. Configuration Parameters Reference
45.12 Least Cost Routing Parameters
The Least Cost Routing (LCR) parameters are described in the table below.
LCR Parameters
Parameter Description
Web: Routing Rule Groups
Table
[RoutingRuleGroups]
This table parameter enables the LCR feature and configures the
average call duration and default call cost. The default call cost
determines whether routing rules that are not configured with a Cost
Group are considered as a higher or lower cost route compared to
other matching routing rules that are assigned Cost Groups.
[ RoutingRuleGroups ]
FORMAT RoutingRuleGroups_Index =
RoutingRuleGroups_LCREnable,
RoutingRuleGroups_LCRAverageCallLength,
RoutingRuleGroups_LCRDefaultCost;
[ \RoutingRuleGroups ]
Note: For a detailed description of this table, see 'Enabling LCR and
Configuring Default LCR' on page 194.
Web: Cost Group Table
EMS: Cost Group
Provisioning > Cost Group
[CostGroupTable]
This table parameter configures the Cost Groups for LCR, where
each Cost Group is configured with a name, fixed call connection
charge, and a call rate (charge per minute).
[ CostGroupTable ]
FORMAT CostGroupTable_Index =
CostGroupTable_CostGroupName,
CostGroupTable_DefaultConnectionCost,
CostGroupTable_DefaultMinuteCost;
[ \CostGroupTable ]
For example: CostGroupTable 2 = "Local Calls", 2, 1;
Note: For a detailed description of this table, see 'Configuring Cost
Groups' on page 196.
Web: Cost Group > Time
Band Table
EMS: Time Band
Provisioning > Time Band
[CostGroupTimebands]
This table parameter configures time bands and associates them
with Cost Groups.
[CostGroupTimebands]
FORMAT CostGroupTimebands_TimebandIndex =
CostGroupTimebands_StartTime, CostGroupTimebands_EndTime,
CostGroupTimebands_ConnectionCost,
CostGroupTimebands_MinuteCost;
[\CostGroupTimebands]
Note: For a detailed description of this table, see 'Configuring Time
Bands for Cost Groups' on page 197.