Parameter Description
EMS: MF R1 Enable
[MFR1DetectorEnable]
Enables the detection of MF-R1 signaling.
ï‚§ [0] = Disable (default)
ï‚§ [1] = Enable
EMS: R1.5 Detection Standard
[R1DetectionStandard]
Determines the MF-R1 protocol used for detection.
ï‚§ [0] = ITU (default)
ï‚§ [1] = R1.5
Note: For this parameter to take effect, a device reset is required.
EMS: User Defined Tone
Enable
[UserDefinedToneDetectorE
nable]
Enables the detection of User Defined Tones signaling, applicable
for Special Information Tone (SIT) detection.
ï‚§ [0] = Disable (default)
ï‚§ [1] = Enable
EMS: SIT Enable
[SITDetectorEnable]
Enables SIT detection according to the ITU-T recommendation
E.180/Q.35.
ï‚§ [0] = Disable (default)
ï‚§ [1] = Enable
To disconnect IP-to-ISDN calls when a SIT tone is detected, the
following parameters must be configured:
ï‚§ SITDetectorEnable = 1
ï‚§ UserDefinedToneDetectorEnable = 1
ï‚§ ISDNDisconnectOnBusyTone = 1 (applicable for Busy, Reorder
and SIT tones)
Another parameter for handling the SIT tone is SITQ850Cause,
which determines the Q.850 cause value specified in the SIP
Reason header that is included in a 4xx response when a SIT tone
is detected on an IP-to-Tel call.
To disconnect IP-to-CAS calls when a SIT tone is detected, the
following parameters must be configured:
ï‚§ SITDetectorEnable = 1
ï‚§ UserDefinedToneDetectorEnable = 1
ï‚§ DisconnectOnBusyTone = 1 (applicable for busy, reorder, and
SIT tones)
Notes:
ï‚§ For this parameter to take effect, a device reset is required.
ï‚§ The IP-to-ISDN call is disconnected on detection of a SIT tone
only in call alert state. If the call is in connected state, the SIT
does not disconnect the call. Detection of busy or reorder tones
disconnect these calls also in call connected state.
ï‚§ For IP-to-CAS calls, detection of busy, reorder, or SIT tones
disconnect the call in any call state.
EMS: UDT Detector Frequency
Deviation
[UDTDetectorFrequencyDevi
ation]
Defines the deviation (in Hz) allowed for the detection of each
signal frequency.
The valid range is 1 to 50. The default is 50.
Note: For this parameter to take effect, a device reset is required.
EMS: CPT Detector Frequency
Deviation
[CPTDetectorFrequencyDevi
ation]
Defines the deviation (in Hz) allowed for the detection of each CPT
signal frequency.
The valid range is 1 to 30. The default is 10.
Note: For this parameter to take effect, a device reset is required.

Table of Contents

Other manuals for AudioCodes Mediant 2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 2000 and is the answer not in the manual?

AudioCodes Mediant 2000 Specifications

General IconGeneral
BrandAudioCodes
ModelMediant 2000
CategoryGateway
LanguageEnglish

Related product manuals