EasyManua.ls Logo

AudioCodes Mediant 2000

AudioCodes Mediant 2000
702 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Version 6.6 691 Mediant 2000
User's Manual 45. Configuration Parameters Reference
Parameter Description
Web: Enable Pattern
Detector
[EnablePatternDetector]
Enables the Pattern Detector (PD) feature.
[0] Disable (default)
[1] Enable
[PDPattern]
Defines the patterns that can be detected by the Pattern Detector.
The valid range is 0 to 0xFF.
Note: For this parameter to take effect, a device reset is required.
[PDThreshold]
Defines the number of consecutive patterns to trigger the pattern
detection event.
The valid range is 0 to 31. The default is 5.
Note: For this parameter to take effect, a device reset is required.