Description of the Software Modules and Parameters
Parameter manual b maXX BM3000
Document no.: 5.12001.07
125
of 820
4
19.52 Modus motor operating mode
107.1 Version
Version of the data structure.
107.2 Motor type
Motor type as a character string, e.g.: "DS 71-K".
107.3 Article number
Article number of the motor on motors with an electronic identification plate. The value
displayed is read from motors with an electronic identification plate and is for information
only.
107.4 Serial number
Serial number of the motor. The value displayed is read from motors with an electronic
identification plate and is for information only.
107.5 Nominal operation mode
At Baumüller, the operating mode of the motor is specified in the form Sx-yy%.
The high byte of the mode is designated by the number in front of the dash, the low byte
encodes the percentage value.
Using the example of S3-40%:
High byte = 3 decimal,
Low byte = 40 decimal.
Value Meaning
0 With encoder, observer off
1 With encoder, observer on
2 Motor model for the motor control (sensorless)