EasyManua.ls Logo

Baumuller b maXX BM3000 - Description of the Parameters

Baumuller b maXX BM3000
822 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Description of the Software Modules and Parameters
Parameter manual b maXX BM3000
Document no.: 5.12001.07
259
of 820
4
4.4.16.3 Description of the Parameters
124.1 Configuration mode
Configuration of the measuring encoder
124.5 Encoder 1 trigger digital input
TP1 pos. edge revolutions
UDINT 0 0xFFFFFFFF 0 1:1 X
124.6 Encoder 1 trigger digital input
TP1 pos. edge angle
UDINT 0 0xFFFFFFFF 0 1:1 X
124.7 Encoder 1 trigger digital input
TP1 neg. edge revolutions
UDINT 0 0xFFFFFFFF 0 1:1 X
124.8 Encoder 1 trigger digital input
TP1 neg. edge angle
UDINT 0 0xFFFFFFFF 0 1:1 X
124.9 Encoder 1 trigger digital input
TP2 pos. edge revolutions
UDINT 0 0xFFFFFFFF 0 1:1 X
124.10 Encoder 1 trigger digital input
TP2 pos. edge angle
UDINT 0 0xFFFFFFFF 0 1:1 X
124.11 Encoder 1 trigger digital input
TP2 neg. edge revolutions
UDINT 0 0xFFFFFFFF 0 1:1 X
124.12 Encoder 1 trigger digital input
TP2 neg. edge angle
UDINT 0 0xFFFFFFFF 0 1:1 X
124.13 Encoder 1 trigger zero pulse
pos. edge revolutions
UDINT 0 0xFFFFFFFF 0 1:1 X
124.14 Encoder 1 trigger zero pulse
pos. edge angle
UDINT 0 0xFFFFFFFF 0 1:1 X
124.15 Encoder 1 trigger zero pulse
neg. edge revolutions
UDINT 0 0xFFFFFFFF 0 1:1 X
124.16 Encoder 1 trigger zero pulse
neg. edge angle
UDINT 0 0xFFFFFFFF 0 1:1 X
124.30 DS402 mode UDINT 0 0xFFFFFFFF 0x00100100 1:1 X
124.31 DS402 touch probe 1 pos.
value
UDINT 0 0xFFFFFFFF 0 Inc 1:1 X
124.32 DS402 touch probe 1 neg.
value
UDINT 0 0xFFFFFFFF 0 Inc 1:1 X
124.33 DS402 touch probe 2 pos.
value
UDINT 0 0xFFFFFFFF 0 Inc 1:1 X
124.34 DS402 touch probe 2 neg.
value
UDINT 0 0xFFFFFFFF 0 Inc 1:1 X
NOTE!
All measurements are inactive during the change of the configuration!