4.4.11 Digital Outputs
The special function „Triggering holding brake“ is available in addition to the free connec-
tions to parameters.
4.4.11.1 ProDrive Digital Outputs
Figure 94: ProDrive Digital outputs
4.4.11.2 Parameter overview
Functional block: DigOutputs [117]
Function DO1 DO2
Triggering holding brake X X
Number Name Type Min Max Default Value Unit Factor
Read only
Storage
DS Support
Cyclic Write
117.1 Status digital outputs DWORD 0 0xFFFFFFFF 0 1:1 X
117.2 Mode digital output 1 WORD 0 0xFFFF 0 1:1 X
117.4 Source number digital output
1
UDINT 0 0xFFFFFFFF 0 1:1 X
117.5 Bit selection digital output 1 DWORD 0 0xFFFFFFFF 0 1:1 X
117.6 Compare bit pattern digital
output 1
DWORD 0 0xFFFFFFFF 0 1:1 X
117.7 Mode digital output 2 WORD 0 0xFFFF 0 1:1 X
117.9 Source number digital output
2
UDINT 0 0xFFFFFFFF 0 1:1 X
117.10 Bit selection digital output 2 DWORD 0 0xFFFFFFFF 0 1:1 X
117.11 Compare bit pattern digital
output 2
DWORD 0 0xFFFFFFFF 0 1:1 X
117.22 Mode DWORD 0 0xFFFFFFFF 0 1:1 X X
117.23 Bit mask digital outputs WORD 0 0xF 0 1:1 X