Parameter manual b maXX BM3000
Document no.: 5.12001.07 Baumüller Nürnberg GmbH
392
of 820
4.5
4.5.5.4 ProDrive Signal bus
Figure 131: ProDrive Signal bus
4.5.5.5 Parameter overview
Functional block: FbSignalbus [140]
4.5.5.6 Description of the Parameters
140.1 Mode
Specifies how the Signal bus in the drive is evaluated and actuated.
Number Name Type Min Max Default Value Unit Factor
Read only
Storage
DS Support
Cyclic Write
140.1 Mode WORD 0 0xFFFF 0 1:1 X
140.2 Status WORD 0 0xFFFF 0 1:1 X
Bit no. Meaning
0 0: Activate Signal bus
1: Completely deactivate Signal bus
1 0: Signal Chopper Resistor On is not generated
1: Set Chopper Resistor On signal, if the DC link voltage exceeds the bal-
last switch on threshold.
9 .. 2 Reserved
10 0: Evaluate Supply ready for use signal
1: Ignore Supply ready for use signal