Description of the Software Modules and Parameters
Parameter manual b maXX BM3000
Document no.: 5.12001.07
387
of 820
4
4.5.4.2 Description of the Parameters
100.1 Error Command
Command for the Info Manager.
100.2 Error Count
Returns the number of errors present in the error memory since the last switch-on or since
the last error reset.
Number Name Type Min Max Default Value Unit Factor
Read only
Storage
DS Support
Cyclic Write
100.1 Error command UINT 0 65535 0 1:1 X
100.2 Error count UINT 0 20 0 1:1 X
100.3 Error information RE-
CORD
X
100.4 Error reaction RE-
CORD
X
100.5 First error UDINT 0 5000 0 1:1 X
100.7 Error communication mode UINT 0 0xFFFF 0 1:1 X
100.8 Error reaction actual value INT -5 3 -1 1:1 X
100.9 Error reaction set value INT -5 3 -1 1:1 X
100.11 Launch application error UDINT 0 0xFFFFFFFF 0 1:1 X
Value Meaning
0 Reserved
1 Reset all errors
Parameter is supported for compatibility reasons, use instead of that
Z108.1– Control Word 1 bit 7 as far as possible
2 Reset all error responses to the default values
4 Reset all errors
Parameter is supported for compatibility reasons, use instead of that
Z108.1– Control Word 1 bit 7 as far as possible
5 Trigger application error no. 169
6 Reset error memory
Remain-
der
Reserved