EasyManua.ls Logo

Baumuller b maXX BM3000 - Description of the Parameters

Baumuller b maXX BM3000
822 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuration
Parameter manual b maXX BM3000
Document no.: 5.12001.07 Baumüller Nürnberg GmbH
240
of 820
4.4
4.4.14.4 Description of the Parameters
29.1 Command
Switching the filter on/off:
Number Name Type Min Max Default Value Unit Factor
Read only
Storage
DS Support
Cyclic Write
29.1 Command UINT 0 1 0 1:1 X
29.2 Status UINT 0 1 0 1:1 X
29.6 Input value FLOAT -5000000000 5000000000 0.000000e+00 1:1 X
29.7 Output value FLOAT -5000000000 5000000000 0.000000e+00 1:1 X
29.8 Filter order UINT 0 7 1 1:1 X
29.9 Coefficient a0 FLOAT -1000000 1000000 1.0 1:1 X
29.10 Coefficient a1 FLOAT -1000000 1000000 0.0 1:1 X
29.11 Coefficient a2 FLOAT -1000000 1000000 0.0 1:1 X
29.12 Coefficient a3 FLOAT -1000000 1000000 0.0 1:1 X
29.13 Coefficient a4 FLOAT -1000000 1000000 0.0 1:1 X
29.14 Coefficient a5 FLOAT -1000000 1000000 0.0 1:1 X
29.15 Coefficient a6 FLOAT -1000000 1000000 0.0 1:1 X
29.16 Coefficient a7 FLOAT -1000000 1000000 0.0 1:1 X
29.17 Coefficient b1 FLOAT -1000000 1000000 0.0 1:1 X
29.18 Coefficient b2 FLOAT -1000000 1000000 0.0 1:1 X
29.19 Coefficient b3 FLOAT -1000000 1000000 0.0 1:1 X
29.20 Coefficient b4 FLOAT -1000000 1000000 0.0 1:1 X
29.21 Coefficient b5 FLOAT -1000000 1000000 0.0 1:1 X
29.22 Coefficient b6 FLOAT -1000000 1000000 0.0 1:1 X
29.23 Coefficient b7 FLOAT -1000000 1000000 0.0 1:1 X
29.29 Filter cycle time FLOAT 62.5 1000 250 µs 1:1 X
Value Meaning
0 Switch off filter
1 Switch on filter

Table of Contents