29.2 Status
Display of filter status (on / off):
29.6 Input value
Displays the input to the filter.
29.7 Output value
Displays the output of the filter.
29.8 Filter order
The filter order can be entered here.
In order to change the parameters the filter either must be deactivated (Z29.1 = 0) or
the pulses must be inhibited.
29.9 Coefficient a0
Using this parameter, the filter coefficients for the particular axis (ZFig. 101on page
236) can be entered accordingly (in the numerator polynomial).
In order to change the parameter the filter either must be deactivated (Z29.1 = 0) or the
pulses must be inhibited.
29.10 Coefficient a1
For description, see Parameter Z29.9.
29.11 Coefficient a2
For description, see Parameter Z29.9.
Value Meaning
0 Filter is switched off
1 Filter is switched on