Description of the Software Modules and Parameters
Parameter manual b maXX BM3000
Document no.: 5.12001.07
433
of 820
4
4.6.5.8 Parameter Overview
Function block: FbKurvengenerator[159]
4.6.5.9 Description of the Parameters
159.1 Mode
Control of cam generator
Number Name Type Min Max Default Value Unit Factor
Read only
Storage
DS Support
Cyclic Write
159.1 Mode WORD 0 0x00FF 0 1:1
159.2 Cam options WORD 0 0xFFFF 0 1:1 X
159.3 Status UINT 0 0xFFFF 0 1:1 X
159.4 List index UINT 0 0xFFFF 0 1:1 X
159.5 List entries UINT 0 0xFFFF 512 1:1 X
159.6 Cyclic curve offset UDINT 0 0xFFFFFFFF 0 1:1 X
159.7 Reference parameter UDINT 0 0xFFFFFFFF 0 1:1 X
159.9 Speed virtual master INT -32768 32767 256 1:1 X
159.10 Position virtual master DINT 0 0x7FFFFFFF 0 1:1 X
159.11 Input parameter UDINT 0 0xFFFFFFFF 0 1:1 X
159.14 Basic value index calculation UDINT 0 0xFFFFFFFF 0 1:1 X
159.15 Shift factor index calculation UINT 0 32 0 1:1 X
159.16 Output parameter UDINT 0 0xFFFFFFFF 0 1:1 X
Bit no. Meaning
0 Activation of the cam generator
Request of state change in state machine of cam generator from "init" to
"active".
0 1: Activation of the cam generator
1 Starting the cam generator
The processing of the cam is initiated with a rising edge in this bit. This
causes a state change of the state machine of the cam generator from
"active" to "run".
0 1: Start the processing of the cam
2 The processing of the cam generator is stopped. The table index is reset.
0: Cam generator can be started and operated
1: Cam generator is stopped and is reset