Configuration
Parameter manual b maXX BM3000
Document no.: 5.12001.07 Baumüller Nürnberg GmbH
202
of 820
4.4
123.2 Status
This parameter shows the current status of the identification.
NOTE!
There is no way proving, if dead time measurement was executed by "Adaption ac-
cording to PWM frequency", successfully.
Value Meaning
0 Identification inactive or completed
1 Preparation for identification
2 Identification starting
3 Switch on voltage setting
4 Voltage setting
5 Starts identification of the resistance
6 Identification of resistance or inductance
7 Error during identification of resistance or inductance
8
Identification of dead time in progress
9
10
11
12
13 Error during identification of dead time
14 Identification ready
15 Identification switched off
16 Identification cannot be switched on
17 Identification error: Set Value voltage too great.
18 Identification error: Voltage limit accessed
19 Identification error: Timeout (60 seconds) while measuring the resistance
20 Identification interrupted
21 Identification finished successfully
22 Identification switched off / aborted
30 Motor diagnosis active