Description of the Software Modules and Parameters
Parameter manual b maXX BM3000
Document no.: 5.12001.07
229
of 820
4
144.2 Scaling factor analog input 1
Scaling factor for Analog Input 1
144.3 Offset analog input 1
Offset for Analog Input 1
144.4 Threshold analog input 1
Threshold value of Analog Input Signal 1 for setting the response sensitivity
144.5 Value analog input 1
Input value of analog input signal on Channel 1
The input signal after PT
1
smoothing and offset correction is displayed.
144.6 Target number analog input 1
Number of the parameter to be changed by Analog Input 1. All cyclic writable parameters
are permitted.
144.20 Time slot analog inputs
This parameter specifies the sampling interval in which the analog input is read.
Setting the parameters to the values 0, 1, 2, 3 corresponds to the relationship n= 0, 1, 2, 3
Value Sampling interval [µs]
0 125
1 250
2 500
3 1000