Configuration
Parameter manual b maXX BM3000
Document no.: 5.12001.07 Baumüller Nürnberg GmbH
306
of 820
4.4
This is a RECORD type parameter (array).
165.6 Latch
The result of a bitwise OR operation with a configurable status Z165.2– is indicated at
the end of each cycle.
Here one-time statuses in the status bits are saved.
This parameter can be written to, in order to reset single bits or the complete latch.
Switching off single channels or the complete function has no effect on its value.
Index Meaning
0 Logic Operator (OP0
a)
) for status bit 16 of Z165.2–
a)
This abbreviation is used for the logic operations in the logic structure
1 Logic Operator (OP1
a)
) for status bit 17 of Z165.2–
… …
14 Logic Operator (OP14
a)
) for status bit 30 of Z165.2–