EasyManuals Logo

Baumuller b maXX BM3000 User Manual

Baumuller b maXX BM3000
822 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #513 background imageLoading...
Page #513 background image
Description of the Software Modules and Parameters
Parameter manual b maXX BM3000
Document no.: 5.12001.07
513
of 820
4
151.5 Lower threshold absolute
If the data type of the parameter selected with Z151.3 is FLOAT, then this parameter
forces the lower absolute switching threshold.
The absolute two-level controller switches on, if the following is valid:
Parameter number actual value  lower absolute switching threshold
151.6 Upper threshold absolute
If the data type of the parameter selected with Z151.3 is FLOAT, then this parameter
forces the upper absolute switching threshold.
The absolute two-level controller switches off, if the following is valid:
Parameter number actual value  upper absolute switching threshold
151.10 Target number
Selection of the target parameter of the absolute two-level controller output.
151.11 Bit selection
Selection of the bits to be changed of the target parameter for the absolute two-level con-
troller output.
151.12 Bit pattern LOW
Bit pattern which is written in the target parameter at absolute two-level controller output
LOW (negative edge).
151.13 Bit pattern HIGH
Bit pattern which is written to the target parameter at absolute two-level controller output
HIGH (positive edge).
151.14 Lower threshold absolute UDINT
If the data type of the parameter selected with Z151.3 is INT, DINT, UINT, UDINT,
WORD or DWORD, then this parameter forces the lower absolute switching threshold.

Table of Contents