Operating Modes
Parameter manual b maXX BM3000
Document no.: 5.12001.07 Baumüller Nürnberg GmbH
686
of 820
4.8
122.16 Master standstill threshold
The standstill threshold is specified to monitor if the master axis stands still during the
synchronization phase.
122.17 Target position offset
The parameter specifies the target position for the overlaid compensating movement
during operation. The parameter has the following format:
122.18 Maximum speed offset
The value of this parameter in Inc/ms specifies the maximum speed of the overlaid com-
pensating movement during the active operation, by which the drive overlays the polyno-
mial curve.
The resolution is 16 bit increments/revolution per ms.
122.19 Maximum acceleration offset
The value of this parameter in Inc./ms
2
specifies the maximum acceleration of the over-
laid compensating movement during the active operation by which the drive overlays the
polynomial curve.
The resolution is 16 bit increments/revolution per ms
2
.
122.20 Maximum deceleration offset
The value of this parameter in Inc/ms
2
specifies the maximum deceleration of the overlaid
compensating movement during the active operation by which the drive overlays the poly
-
nomial curve.
The resolution is 16 bit increments/revolution per ms
2
.
1 bit 15 bit 16 bit
Sign Revolutions Angle

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Baumuller b maXX BM3000 and is the answer not in the manual?

Baumuller b maXX BM3000 Specifications

General IconGeneral
BrandBaumuller
Modelb maXX BM3000
CategoryMeasuring Instruments
LanguageEnglish