104.21 FFT data
The result of the analysis is shown here as an Array parameter. The data is assigned as
follows:
FFT Data[0]: Amplitude process in the dB
FFT Data[1]: Phase process in the degree
FFT Data[2]: Coherence
FFT Data[3]: Spectrum Signal_1, in the dB
FFT Data[4]: Spectrum Signal_2, in the dB
FFT Data[5]: Cross spectrum, real
FFT Data[6]: Cross spectrum, imaginary
104.22 Prbs register length
Length of the Prbs register.
104.23 Prbs register clock
Clock frequency of the Prbs register. Value corresponds to a whole multiple of the RT0
cycle.